So this is what we start with. Otherwise, a cheap sacrificial filter will do the job. If the pipe is already buried, there is no need to dig up and expose the pipe to apply insulation. Old style removal old style pitless adapter removal. Anyway, I don't like it when my water pressure is set for 40/60. Well... the well pump is only 4" wide. It would either be a pitless adapter or a union. Writing about these things is, frankly, a more fertile field for the writer, especially if he happens to like them. Normally, the Horsepower Rating is written (as a courtesy) on the underside of the well cap.

Pitless Adapter Removal Tool

Run the hose for about an hour to get the water from the bottom all the way back up to the top, ensuring that the chlorine mixes with ALL the water in the well. You do not need to tape the cable to the water pipe, but you can. The chlorine will sit in your pipes and kill off anything living in them. In some cases, experienced tradespeople have reported inserting Retro-Line units of longer lengths without the need of a pull cord or plumbers' fish. Only one image can be added per comment but you can post as many comments, and therefore images, as you like. Hi guys, I was at work the other day (I drill wells and install pumps and pressure tanks) and thought to myself, this might be something useful to take to the gj boards. This method can bring the ell up at about 3 feet at time before needing to reposition the brackets which I used to hold the well on the side of the 4 well casing. Post your water well and pump questions. For example a 20 ft (6. If the kit is for a PVC casing, it will include a curved plate that goes between the U bolt and the casing so tightening will not crush the more fragile plastic material. Then run your hose down the well to circulate the bleach. The most common application for slide pitless adapters is for submersible pumps. In applications where the existing problematic potable water supply pipe is exposed and above ground, the simplest method of measuring is with an external measuring device such as a measuring tape and/or flexible ruler. In a drilled well application, the heater can run the length of the pipe, but cannot enter the pitless adapter or it may sustain damage. For example, if an 18ft.

"It's awfully inconvenient for them to be down so far in the well. " Take the pipe, flatten one end leaving enough clearance for the inside to fit over a wingnut and make a handle on the opposite end. Reduced water in the tank means reduced pressure. Build Robby: Replacing Well Pump And Unlocking Pitless Adapter. If a shorter system is needed it can be shipped back to Heat-Line to be shortened or it can be shortened at the job-site by following careful extraction instructions. Retro-Line can be found providing freeze protection in many of the following places: - Homes, cottages, resorts and farms. For polyethylene pipe applications Retro-Line is supplied with a compression style fitting for easy connection to the pipe.

Old Style Removal Old Style Pitless Adapter Removal

For pressurized sewage forced mains and large diameter potable water supply pipes see Retro-FM. Have your assistant go down into the basement and flip the breaker that will turn on the pump. For a list of Heat-Line product distributors in Canada and the United States please contact Heat-Line directly on our toll-free number at. Yet another application in which such a simple tool can be incredibly useful. How to Replace a Submersible Well Pump : 29 Steps (with Pictures. Examples include but are not limited to: - Lake and river water supply. Most clamp ons come as a kit, which includes four parts. Salvage the remaining hose clamps and get ready to cut the water tube. If it does, the pump is ready to go back down in the hole! Retro-Line self-regulating heating cable systems increase heat output with cold but more importantly, decrease heat output with warmth. Here's what you do: Dump about 3/4 of the gallon of bleach in the well (with the water pump still on, so you can still use your hose). Suitable pipe types for Retro-Line include but are not limited to: - Polyethylene (ID and OD controlled).

They are also sometimes used to install the drop pipe and foot valve in shallow well jet pump systems. Any ideas or suggestions would be greatly appreciated. To make one of these wrenches you just go down to the local hardware store, buy the threaded pipes and put them together. See Catalog 570, page 72. Pitless adapter removal tool. As I mentioned above, the connectors are usually brass. Remember how I told you that my well casing is 6" wide? Once you get them all off, set them in a safe place for later. In a drilled or dug well application the Retro-Line system should start in the heated building or room and end (terminate) at the well casing. The 3/4" HP pump that was currently in the hole weights about a total of 60 lbs when it is in water, meaning still deep inside the well tube. While you do that, make sure someone is holding onto the safety rope!

Old Style Removal Old Style Pitless Adapter Kit

You never have to worry about the Retro-Line pipe heating cable overheating causing a risk of melting and fire because of the self-regulating pipe heating cable technology. Retro-DWS is designed for safe and approved installations inside non-pressurized septic pipes and or in large drains where mechanical protection of the heater is desired. If they aren't, all it will take is one really cold night to freeze up. Note: This is one of those moments where it's good to get along with your neighbors. We have absolutely no snow on the ground. Make sure the water and pump is turned off before doing this. This well was located indoors in a New York home - not a great idea - in the building basement. Old style removal old style pitless adapter pipe. Bottom line: I'm guessing that I had to pull a 70lb weight, nearly 100 vertical feet. You may be in the same boat when it's time to do yours. A – Insulation is highly recommended when using the Retro-Line system, especially if the installation is above ground in ambient outdoor air. Q – Can Retro-Line be cut if too long?

Our goal is to provide an understanding of exactly what they are, what the differences are and what they do. Another advantage of the pipe heater wire durability is the downward end of the cable does not need to be fastened as it will never move or slide up the pipe with the flow of the water. The deeper the well, the more weight you're dealing with. This certification and feature are unmatched by standard electric heat tape for pipes with thermostats, pipe heater wires, heat trace tapes, and plumbing heat tapes. It only runs about 100'-120' deep. Step 20: Selecting a Replacement Pump at the Hardware Store. Please do not push hard to make sure it is seated properly since this can damage the well casing.

Old Style Removal Old Style Pitless Adapter Pipe

Q – Can Retro-Line be installed inside septic pipes? You will need to match its specifications for the new pump. You never know who you might be helping! I have heard of people drilling the casing with a drill bit as small as ½ inches, but I don't think this is recommended by the manufacturers. The water connection might make it hard to see past it but a hint is white PVC is reflective, black flex pipe is not reflective and dull. After digging down past the pittless adapter a leak was revealed at the junction of the brass nipple to the coupling going into the pitless.

Yet you will notice price decreases in our nipples and rough brass threaded fittings. TURN ON EVERY TAP IN THE HOUSE, SEQUENTIALLY. Even in applications where the pipes are intended to be dry for short or extended periods of time such as sump pump lines, the Retro-Line presents no danger of overheating or melting the pipe. Especially when, after a couple of minutes pulling up the well pump, you realize that you've been making some very poor decisions about exercise and eating habits.

Add a 1/8" stainless steel cable to the pump to make removal next time easier. I'm not sure when the last time you had to dig a 4' deep hole was, but I can assure you it's not a pleasant thing to have to do. Line up the pitless connector, using a flashlight. You will also need 6 stainless steel cable clamps, use 3 at each end.